Contact Us
Mobile:18032796331
Mobile:13739612731
Email:3916927@qq.com
Building 2, Area C, Fangyi Technology Park, High-tech Zone, Shijiazhuang City, Hebei Province
320/400KW Integrated Dual-Gun DC Charging Pile
- Product Description
-
Technical Parameters
Power Rating
320KW
400KW
Input Voltage
304 - 465VAC
304 - 465VAC
Input Frequency
45 - 68HZ
45 - 68HZ
Output Voltage
50 - 1000V DC
50 - 1000V DC
Output Power
Output 40KW - 320KW depending on module configuration
Output 40KW - 400KW depending on module configuration
Maximum Current
Single gun 250A, dual gun 500A
Single gun 300A, dual gun 600A
Gun Cable Length
7M
7M
System Efficiency
≥96%
≥96%
Protection Level
IP54
IP54
Power Factor
>0.99
>0.99
Standards
CCS1, CCS2, GB/T, CHAdeMo
Auxiliary Power Supply
12V, 24V (optional)
12V, 24V (optional)
Start Method
Scan code, VIN, password charging
Scan code, VIN, password charging
Communication Interface
4G
4G
Cooling Method
Independent Air Duct
Independent Air Duct
Operating Temperature
-30℃ - 55℃
-30℃ - 55℃
Relative Humidity
5% - 95% non-condensing
5% - 95% non-condensing
Operating Altitude
≤2000m
≤2000m
Protection Functions
Overvoltage, undervoltage, overload protection, short circuit protection, grounding protection, surge protection, leakage protection
Overall Dimensions
W×D×H 950×800×1900mm
W×D×H 950×800×1900mm
Charging Pile Installation Process
>> Concrete grade not less than C20, underground part height not less than 400mm, above ground part height not less than 200mm, concrete foundation size length*width 1150*1000mm, appearance complete, flat, no cracks. See the outline below:

Cable Installation
Charging Pile Power
Recommended Cable (Copper) Model mm²
Recommended Cable (Aluminum) Model mm²
320kW Dual-gun Integrated Pile
YJV - 3*185 + 2*95
Two YJV - 3*240 + 2*120
400kW Dual-gun Integrated Pile
YJV - 3*185 + 2*95
Two YJV - 3*240 + 2*120
>> AC input line wiring starts from the user distribution switch, connected to the switch output terminal just before power-on.
>> The distribution area should have overcurrent, short circuit, and lightning protection devices.
>> AC power line colors yellow, green, red, light blue correspond to AC phases A, B, C and neutral line respectively.
>> If power lines have only one color, line number labels (or marked sleeves) must be attached.
>> AC power lines should be laid separately from DC lines.
>> Power lines must not have broken ends, damage, or scratches.
>> Wiring order is generally protective ground first, then neutral, and finally AC phase lines.
>> Before electrical connection, set all switches, fuses, etc. to the off position.
Integrated Photovoltaic Storage and Charging Solution

Case Studies
Packaged Shipping
TAG:
Message
Contact
+8615031966899